AN-691
APPLICATION NOTE
One Technology Way P.O. Box 9106 Norwood, MA 02062-9106 Tel: 781/329-4700 Fax: 781/461-3113 www.analog.com
Operation of RF Detector Products at Low Frequency
by Matthew Pilotte
INTRODUCTION
Analog Devices has many RF detector products in its
portfolio designed to operate over various frequency
ranges up to 8.0 GHz. Most of these parts can also
perform very well at frequencies down into the audio
band, although the data sheets for these parts list
performance and specify guaranteed operation at much
higher frequencies. The low input frequency performance
of these parts is summarized in this application note. Plots
of performance are included.
The low frequency performance of the following parts
is discussed in this application note: AD8302, AD8306,
AD8307, AD8309, AD8310, AD8361, and AD8362. (The
AD8314 is not included because it contains a series
capacitor at its input, which precludes its use at low
frequency.) Using the appropriate precautions, some
of these devices can be dc-coupled at their inputs. The
external circuitry substantially determines the lowest
frequency at which operation is acceptable.
These devices can be grouped into four general catego-
ries: demodulating logarithmic ampliers, exponential
logarithmic ampliers, special purpose circuits employ-
ing demodulating logarithmic ampliers, and rms-to-dc
converters. Table I shows the category into which each
part falls.
Table I.
Part Number Category
AD8302 Special Purpose
AD8306 Demodulating Logarithmic Amplier
AD8307 Demodulating Logarithmic Amplier
AD8309 Demodulating Logarithmic Amplier
AD8310 Demodulating Logarithmic Amplier
AD8361 RF rms-to-dc Converter
AD8362 Exponential Logarithmic Amplier
It is important to understand each of the fundamental
performance parameters for these categories of parts.
The data sheet for each device includes a comprehensive
theory of operation section that goes into detail beyond
what is presented here.
Demodulating Logarithmic Ampliers
ADI’s demodulating logarithmic ampliers (log amps)
produce an output that is proportional to the common
logarithm of the input signal amplitude; this response
is described as being linear-in-dB. The transfer function
produced is a straight line when plotted against the input
signal magnitude, expressed in decibels. This straight line is
described in ADI data sheets by its slope and its x intercept.
Because these log amps are very sensitive, the response
to the tiny amount of noise that is inevitably generated in
the input sections of the log amps is indistinguishable at
the detector output from the response to very small input
signals. Consequently, the detected output voltage typically
does not go to 0 V when the amplitude of the input signal
goes to 0 V, but reaches a lower limit that is typically in the
sub-300 mV range as the input signal amplitude nears 0 V.
The x intercept discussed here is the extrapolated point at
which the transfer function would intersect the horizontal
axis, if it were capable of doing so. See Figure 1.
The slope of the transfer function is simply the change
in the detected output voltage over the change in input
signal amplitude, expressed in dB. For log amps, slope is
expressed in terms of millivolts per dB.
Both of these values are determined by performing a
linear regression over the straightest central portion of
the actual detected output voltage versus input signal
level curve. Then, the actual measured voltage at each
input level is compared to that predicted by the linear
regression to determine the law conformance of the part.
The law conformance of an ideal log amp versus input
signal level is 0 dB. In practice, the dynamic range of ADI
log amps is typically dened to be the range over which
the law conformance is ±1 dB maximum.











           


















Figure 1. Basic Log Amp Transfer Function
REV. 0

AD8306ARZ Datenblatt-PDF

AD8306ARZ Datenblatt PDF
ADI
16 Seiten, 398 KB
AD8306ARZ Anderes Datenblatt
ADI
8 Seiten, 153 KB
AD8306ARZ Anwendungshinweis
ADI
16 Seiten, 779 KB
AD8306ARZ Andere Referenzen
ADI
1 Seiten, 187 KB

AD8306 Datenblatt-PDF

AD8306
Datenblatt PDF
ADI
5MHz TO 400MHz, 100dB High Precision Limiting - Logarithmic Amplifier
AD8306ARZ
Datenblatt PDF
ADI
ANALOG DEVICES AD8306ARZ Logarithmic Amplifier, 6 Amplifier, 100dB, 73ns, SOIC, 16Pins
AD8306AR
Datenblatt PDF
ADI
SOIC 400MHz 95dB DEMODULATING LOG AMP
AD8306ARZ-RL7
Datenblatt PDF
ADI
SOIC 400MHz 95dB DEMODULATING LOG AMP
AD8306-EVALZ
Datenblatt PDF
ADI
5MHz-400MHz 100dB High Precision Limiting-logarithmic Amplifier
AD8306AR-REEL7
Datenblatt PDF
ADI
SOIC 400MHz 95dB DEMODULATING LOG AMP
AD8306AR-REEL
Datenblatt PDF
ADI
SP Amp LOG Amp Single 6.5V 16Pin SOIC N T/R
AD8306ARZ-REEL
Datenblatt PDF
ADI
5MHz TO 400MHz, 100dB High Precision Limiting - Logarithmic Amplifier Package: 16 ld SOIC; No of Pins: 16; Temperature Range: INDUSTRIAL; Container: 2500/Reel
AD8306ACHIPS
Datenblatt PDF
ADI
5MHz TO 400MHz, 100dB High Precision Limiting - Logarithmic Amplifier
AD8306EVAL
Datenblatt PDF
ADI
Datenblatt-PDF-Suche
Suche
100 Millionen Datenblatt-PDF, aktualisieren Sie mehr als 5.000 PDF-Dateien pro Tag.
Dokumentation beziehen: AD8306 Datenblatt PDF
Kontakt online
Bonnie - AiPCBA Sales Manager Online, vor 5 Minuten
Ihre E-Mail *
Nachricht *
Senden