Teiledatenblatt > Pressure Sensor > Honeywell > PX2AF1XX500PACHX Datenblatt-PDF > PX2AF1XX500PACHX Anwendungshinweis Seite 1/4
PX2AF1XX500PACHX
€ 43.97
Preis von AiPCBA

PX2AF1XX500PACHX Anwendungshinweis - Honeywell

  • Hersteller:
    Honeywell
  • Kategorie:
    Pressure Sensor
  • Fallpaket
    Cylinder
  • Beschreibung:
    Pressure Sensor 0psi to 500psi Absolute 3Pin
Aktualisierte Uhrzeit: 2025-04-10 15:16:14 (UTC+8)

PX2AF1XX500PACHX Anwendungshinweis

Seite:von 4
PDF herunterladen
Neu laden
herunterladen
Safety and Productivity Solutions
Heavy Duty Pressure Sensors,
PX2 Series and PX3 Series
An Application Note
Background
Honeywell’s PX2 Series and PX3 Series Heavy Duty Pressure
Transducers are a portfolio of highly configurable pressure sensors that
use piezoresistive sensing technology with ASIC (Application Specific
Integrated Circuit) signal conditioning in a metal housing. These products
are fully calibrated and compensated for offset, sensitivity, temperature
effects and non-linearity using the on-board ASIC. The Total Error
Band, which provides the most comprehensive, clear, and meaningful
specification of the sensor’s measurement performance, is ±2 %FSS (40
ºC to 125 ºC [40 °F to 257 °F]) for the PX2 Series and ±1 %FSS (20 °C to
85 °C [4 °F to 185 °F]) for the PX3 Series. (See Figure 1.)
Pressure ranges are 1 to 70 bar | 100 kPa to 7 MPa | 15 psi to 1000 psi for
the PX2 Series and 1 bar to 50 bar | 15 psi to 700 psi for the PX3 Series.
All products are designed and manufactured according to ISO 9001
standards and are RoHS and CE compliant.
Solutions
With thousands of possible configurations, the PX2 Series and PX3 Series
allow Honeywell to meet customer requirements and quickly provide
the preferred options for the application. They are compatible with a
variety of harsh media including brake fluid, common hydrofluorocarbon
refrigerants, next generation low global warming potential (GWP)
refrigerants, engine oil, water, hydraulic fluids, and compressed air. The
wide operating temperature range, ingress protection, and radiated
immunity allow for reliable performance in tough environments.
These transducers measure absolute, sealed
gage, or vented gage pressure (PX2 only for
vented gage). The absolute versions have an
internal vacuum reference and an output value
proportional to absolute pressure, the sealed
gage versions have the offset calibrated at 14.7
psiA, and the vented gage versions measure
pressure with respect to ambient pressure. (See
Table 1.)
Potential Applications
Industrial
HVAC/R: May be used to monitor system
performance for proper environmental control of:
• Compressors:
- Inlet and outlet pressure
- Oil pressure
- Rack rooms
• Refrigerant recovery systems
• Rooftop chillers
Air compressors: May be used to monitor
compressor performance and efficiency,
specifically:
• Filter pressure drop
• Inlet and outlet pressure
• Oil pressure
• Pumps
General: May be used to monitor air and fluid
pressure in:
• Cooling water inlet and outlet pressure
• Factory automation
• Flow and level
• Fluid power
• Injection molding knock-out valves
• Lasers
• Pneumatics
• Solar energy
• Sprayers
• Valves
Transportation
• Air system monitoring
• Air brakes
• Cooling systems
• Engine oil
• Hydraulic oil pressure monitoring
• Manifold absolute pressure (MAP)
Figure 1. TEB Definition and Temperature Performance
Total
Error
Band
Accuracy
BFSL
All Possible Errors
Thermal Hysteresis
Thermal Effect on Offset
Thermal Effect on Span
Pressure Non-Linearity
Pressure Hysteresis
Full Scale Span
Offset
Pressure Non-Repeatability
-20 °C
[-4 °F]
-40 °C
[-40 °F]
0
85 °C
[185 °F]
0 °C
[32 °F]
125 °C
[257 °F]
1
2
3
-1
-2
-3
Temperature (°C [°F])
Total Error Band (%FSS)
Total Error Band

PX2AF1XX500PACHX Datenblatt-PDF

PX2AF1XX500PACHX Datenblatt PDF
Honeywell
10 Seiten, 1731 KB
PX2AF1XX500PACHX Anderes Datenblatt
Honeywell
17 Seiten, 2382 KB
PX2AF1XX500PACHX Anwendungshinweis
Honeywell
4 Seiten, 240 KB

PX2AF1XX500 Datenblatt-PDF

PX2AF1XX500PSCHX
Datenblatt PDF
Honeywell
Basic Board Mount Pressure Sensors: TBP Series, ± 0.15% Accuracy, Compensated/Unamplified Analog mV Output, Leadless SMT, Single Axial Barbless Port, 30psi Gage, 1.8-12V Supply, No Gel Coating in Media Path
PX2AF1XX500PAAAX
Datenblatt PDF
Honeywell
HONEYWELL PX2AF1XX500PAAAX Pressure Sensor, Voltage, 500psi, Absolute, 5V, 1/4" - 45° Flare Female Schrader, 4mA
PX2AF1XX500PSBGX
Datenblatt PDF
Honeywell
Pressure Sensor 1V to 5V 0psi to 500psi Sealed Gage 3Pin
PX2AF1XX500PSBEX
Datenblatt PDF
Honeywell
Pressure Sensor 0.5V to 4.5V 0psi to 500psi Sealed Gage 3Pin
PX2AF1XX500PSBCX
Datenblatt PDF
Honeywell
Pressure Sensor 1V to 6V 0psi to 500psi Sealed Gage 3Pin
PX2AF1XX500PGAAX
Datenblatt PDF
Honeywell
Standard, Termination: Packard Metripak 150; Port: 1/4" 45deg Female Schrader, Pressure Rating: 0-500psi, Reference type: Gage, Output Type: Ratiometric 5V, 10%Vs to 90% Vs
PX2AF1XX500PACHX
Datenblatt PDF
Honeywell
Pressure Sensor 0psi to 500psi Absolute 3Pin
PX2AF1XX500PSAAX
Datenblatt PDF
Honeywell
Pressure Sensor 0psi to 500psi Sealed Gage Automotive 3Pin
Datenblatt-PDF-Suche
Suche
100 Millionen Datenblatt-PDF, aktualisieren Sie mehr als 5.000 PDF-Dateien pro Tag.
Kontakt online
Bonnie - AiPCBA Sales Manager Online, vor 5 Minuten
Ihre E-Mail *
Nachricht *
Senden